| Battery Voltage | 9 volt |
| Battery Type | Alkaline |
| Battery Life | 300 hours Typical, without Backlight |
| Maximum Voltage between Any Terminal and Earth Ground | 600 volt |
| Display | 3 3/4-digits, 6000 counts, updates 4/second |
| Operating Temperature | -10 to 50 degree Celsius |
| Storage Temperature | -40 to 60 degree Celsius |
| Temperature Co-Efficient | 0.1 x (Specified Accuracy) / Celsius (< 18 degree Celsius or > 28 degree Celsius) |
| Operating Altitude | 2000 metre |
| Storage Altitude | 10000 metre |
| Relative Humidity | 95 percent to 30 degree Celsius 75 percent to 40 degree Celsius 45 percent to 50 degree Celsius |
| VCHEK1 2 3 | Range | 6.000/60.00/600.0 volt |
| Resolution | 0.001/0.01/0.1 volt |
| Accuracy | DC, 45 to 500 Hz: 2.0 percent + 3 500 Hz to 1 kHz: 4.0 percent + 3 |
| Diode Test4 | Range | 2.000 volt |
| Resolution | 0.001 volt |
| Accuracy | 2.0 percent + 3 |
| Continuity4 | Accuracy | Beeper on < 20 O, off > 250 O detects opens or shorts of 500 µs or longer |
| O4 | Range | 600.0 O/6.000 kO/60.00 kO |
| Resolution | 0.1 O/0.001 kO/0.01 kO |
| Accuracy | 0.9 percent + 2 / 0.9 percent + 1 / 0.9 percent + 1 |
| Capacitance4 | Range | 1000 nF/10.00 µF/100.0 µF/9999 µF |
| Resolution | 1 nF/0.01 µF/0.1 µF/ 1 µF |
| Accuracy | 1.9 percent + 2 100 µF - 1000 µF: 1.9 percent + 2 1000 µF: 5 percent + 20 |
| Vibration | Per MIL-PRF-28800 for Class 2 Instrument |
| VCHEK | Input Impedance (Nominal) | ~3 kO < 300 pF |
| VCHEK | Common Mode Rejection Ratio (1 kO unbalanced) | > 60 dB at DC, 50 or 60 Hz |
| O | Open Circuit Test Voltage | < 2.7 VDC |
| Full Scale Voltage | < 0.7 VDC |
| Diode Test | Open Circuit Test Voltage | 2.7 VDC |
| Full Scale Voltage | 2.000 VDC |
| O | Short Circuit Current | < 350 µA |
| Diode Test | Short Circuit Current | < 1.0 mA |
| Size (H x W x L) | 167.1 x 85.1 x 46.0 mm |
| Weight | 0.404 kg |